Meter Info


The Meter Info tab enables you to display and define meter information related to components.

The Primary Information screen supports department-level and location level access control, so you must belong to a user group with the applicable authorizations to make changes or updates.

Detail View Header

The field in the top section of this tab defines the data that displays.

Equipment ID

Identifier of the component currently selected in the grid or that you are defining. This field has a list box. The component year, manufacturer, and model display to the right of the ID.

When you insert a component with an asset category that supports automatic numbering and this field is blank, the system generates an equipment ID that follows the format specified in the Custom ID structure field on the Data -> Equipment Units -> Setup -> Asset Categories screen. If the asset category does not support automatic numbering, the equipment ID is based on either part/location settings or system settings. If you specify an ID and the component’s asset category supports automatic numbering, the ID is not overwritten.

Whether an asset category supports automatic numbering is specified on the Data -> Equipment Units -> Setup -> Asset Categories screen.

Detail View

Data in the fields in the bottom section of this tab define meter information for the component. Unless otherwise indicated, these fields are required.

Equipment class for meter types

Identifier of the equipment class to which the equipment unit is assigned. It is used to specify the types of meter (or meters) the unit has and to determine meter edit ranges. This field has a zoom button to the Data -> Equipment Units -> Setup -> Equipment Class -> Primary Information screen, on which equipment classes are defined, and a list box of equipment class IDs that have a check in the Meter types field on the Functions tab of that screen. The class name displays to the right of the ID. Required to update meter readings automatically.

The Meter Info tab on the Data -> Equipment Units -> Setup -> Equipment Class -> Primary Information screen defines meter information related to the equipment class ID.

Life total – parent meter 1

Number of meter units the parent equipment unit has operated. This information displays automatically when you specify the equipment ID. This field is display only.

Meter information

Meter 1 and Meter 2

Information about the component's meter (or meters). A component’s assignment to a meter type class (refer to the Equipment class for meter types field) specifies its meter type. This field is optional.

Meter at delivery

Meter reading at the time of the unit’s delivery. It may not be greater than the value specified in the Maximum meter value field. This field is optional. To start tracking costs for existing units from the date of implementation, enter the current meter reading.

Latest meter reading

Last meter reading entered for the component, from this screen or elsewhere in the system. It may not be greater than the value specified in the Maximum meter value field. It may, however, be less than the current meter value. If the class in the Equipment class for meter types field is specified as a meter type other than NONE, the class to which the unit is assigned specifies whether this field is required. (Otherwise it is optional.) If the meter type is NONE, this field must be zero (0).

If you update information in this field, the system updates information in the Current Meter 1 field on the Meters and Fuel tab of the Data -> Equipment Units -> Historical Costs screen for the current month and year.

Latest meter source

Source of the latest meter reading. This field is display only.

This field updates automatically if there is a check in the Update the last meter read source and date if the new meter reading is the same as the old reading field on the Data -> Equipment Units -> Setup -> Meter Source screen and the new meter reading is the same as the old reading.

Meter update sources are defined on the Data -> Equipment Units -> Setup -> Meter Source screen.

Latest meter date

Date and time (in MMDDYYYY HH:MM format) of the latest meter reading by the meter source. This field is display only.

This field updates automatically if there is a check in the Update the last meter read source and date if the new meter reading is the same as the old reading field on the Data -> Equipment Units -> Setup -> Meter Source screen and the new meter reading is the same as the old reading.

Maximum meter value

Maximum possible reading for the designated meter before it rolls over to zero. The value enables the system to detect when a rollover has occurred based on regular meter entries so you do not have to manually record the rollover event. This setting is applied automatically when you create a new equipment record or when you change the equipment class for meter units on an existing equipment unit.

If the Equipment class for meter types field assigns the equipment ID to a class for which the Meter Info tab on the Data -> Equipment Units -> Setup -> Equipment Class -> Primary Information screen specifies a meter type (other than NONE), the class to which the unit is assigned specifies whether information is required in this field.

The field defaults to null. A value is required only if the meter type is other than NONE. This field has a list box:

Life total

Lifetime accumulated meter usage for the equipment unit. If the Equipment class for meter types field assigns the equipment ID to a class for which the Meter Info tab on the Data -> Equipment Units -> Setup -> Equipment Class -> Primary Information screen specifies a meter type (other than NONE), the class to which the unit is assigned specifies whether information is required in this field. If the meter type is NONE, this field must be zero (0).

Meter resets Screen Group Data Table

The fields in the Meter resets screen group record meter replacement and rollover events; they display a complete history of all such events for equipment units. Make a new entry each time you replace a meter in an equipment unit. The system automatically detects meter rollovers and makes appropriate entries for them (identified by a value of ROLLOVER in the Reason field).

Delete

To delete a row, place a check in this field and click Save.

Date

The date the meter was reset.

Meter number

Meter number of the meter. It must be 1.

Reason

Reason the meter was reset. This field has a list box:

New meter value

Reading on the meter immediately after it was reset. This value should be 0 unless the Reason field specifies REPLACEMENT and the new meter has a value greater than 0 (i.e., had been used). The new meter value must not be greater than the maximum meter value.

Old meter value

Last reading on the meter before it was reset. This field is display only. This value depends on the value in the Reason field:

WO location

Identifier of the work order location where the meter was replaced.

-year

Year (in YYYY format) that the meter replacement work order was opened. This field has a list box.

-number