Usage |
The Usage screen enables you to apportion equipment usage across multiple work orders.
Note: Use the Data -> Equipment Activity -> Multi-unit Projects -> Primary Information screen to manage campaigns and other major work that must be performed separately across a large number of equipment units.
The Usage screen has one tab, Basic Info.
Equipment usage to be apportioned across the selected items
Parent work order ID
Identifier of the multiple equipment work order currently selected in the grid or that you are inserting (opening). This field is required. May not be closed.
The work order ID is composed of three parts:
Location identifier of the
shop to which the work order is assigned. Defaults to the location
ID in the user's Session location
ID field on the Basic Info tab of the System Management -> Setup -> Access
Rights -> Users
screen. This field has a list
box of locations that the user has access to as defined on the
System Mgmt -> Setup -> Access
Rights -> Rights Templates -> Location
Access Template screen. The location must support work
orders.
If there is a check in the Require
match between work order location and equipment access rights location
field on the Options tab of the Data
-> Shop Activity -> Setup -> Options
screen, it must be the equipment ID's access rights location ID specified
on the Locations tab of the Data
-> Equipment Units -> Fleet
Equipment screen.
Calendar year in which the work order was opened.
Sequential number in the range from 1 to 9999999.
When you insert (open) a new parent work order, you can assign a work order ID manually or let it be assigned automatically. To have the work order ID assigned automatically, type the location ID where the work order will be filled. The current year fills in automatically and the next sequential number available at that shop is assigned. To change the number, type another number over it.
Task ID
Identifier of the task. This field has a list box. The task ID must consist of valid bar code characters only. You may not post indirect tasks to a work order. This field is required.
If an account ID is entered for the line, the task IDs that display are only those associated with the account. If there are no associated task IDs listed for the account, all active tasks that support that account will display. This does not include accounts that have the Enforce task restrictions for this account option enabled on the Tasks tab of the Accounts Primary Information screen.
Note: The task may not be defined as PM TASK, INDIRECT, GENERAL, or COST STANDARD.
Task IDs are defined on the Data -> Shop Activity -> Setup -> Tasks -> Primary Information screen.
Date
Date (in MMDDYYYY format) that the equipment usage was posted to the work order. Defaults to the current date, but you can change it. Must be the same as or later than the date that the parent work order was opened and earlier than or equal to the finish date of all associated child work orders. This field is required.
If there is a check in the Allow posting when posting date is one day removed from today or work finished date field on the Options tab of the Data -> Shop Activity -> Setup -> Options screen, usage may be posted one day after the finish date.
Hours
Number of hours. Must be greater than or equal to zero. Either this field must have a value, or the Meter 1 begin and Meter 2 begin fields must have values.
Equipment ID
Identifier of the equipment unit. This field has a list box and a zoom button to the Data -> Equipment Units -> Fleet Equipment screen, on which equipment IDs are defined. The equipment unit description displays the right of the ID. Must be an equipment unit that has a check in the Usage tickets field on the Authorization tab of the Data -> Equipment Units -> Fleet Equipment screen. This field is required.
Meter 1 begin
Meter reading on the appropriate meter in the equipment unit at the start of this usage; omit tenths. Either this field and the Meter 2 begin field must values, or the Hours field must have a value. If you enter information in this field, you must also enter a value in the Meter 1 end field.
This value must not be greater than the value in the Meter 1 end field. If the meter has rolled over during the usage, you must split the transaction into two entries.
End
Meter reading on the appropriate meter in the equipment unit at the end of this usage; omit tenths. Must be greater than or equal to zero. Must be within the equipment unit's meter edit range and less than the equipment unit's maximum meter value. May not be less than equipment unit's current meter value unless the meter rolled over (and is still within meter edit range). If you enter information in this field, you must also enter a value in the Meter 1 begin field.
Meter validation
Specifies whether and how meter validation is performed on the meter 1 reading at the time of dispatch. This field has a list box of either EQ UPD or NO EQ UPD. Refer to meter validation fields.
Tip: Meter 2 entries apply only if the equipment unit is assigned to a class with two meters.
Meter 2 begin
Meter reading on the appropriate meter in the equipment unit at the start of this usage; omit tenths. Either this field and the Meter 1 begin field must values, or the Hours field must have a value. If you enter information in this field, you must also enter a value in the Meter 2 end field.
This value must not be greater than the value in the Meter 2 end field. If the meter has rolled over during the usage, you must split the transaction into two entries.
End
Meter reading on the appropriate meter in the equipment unit at the end of this usage; omit tenths. Must be greater than or equal to zero. Must be within the equipment unit's meter edit range and less than the equipment unit's maximum meter value. May not be less than equipment unit's current meter value unless the meter rolled over (and is still within meter edit range). If you enter information in this field, you must also enter a value in the Meter 2 begin field.
Meter validation
Specifies whether and how meter validation is performed on the meter 2 reading at the time of dispatch. This field has a list box of either EQ UPD or NO EQ UPD. Refer to meter validation fields.
Account ID
Identifier of the general accounting system account associated with the equipment usage. This field has a list box. The Edit Criteria - General tab of the Data -> Setup -> Options screen specifies whether this information is required, optional, or not required.
If a task ID is entered for the line, the account IDs that display are only those associated with the task. If there is no associated account ID listed for the task, all active accounts that support that task will display.
Reversal
A check in this field reverses the charges posted in this entry from the work order.
Select all
If this field has a check, usage charges are posted to all the work orders in the screen group.
Select
If this field has a check, the usage charge is posted to the work order in this row.
Equipment ID
Identifier of the equipment unit assigned to the child work order. This field has a list box. This field is display only.
Work order ID
Identifier of the child work order. This field populates automatically when the parent work order ID is specified. This field is display only.